Описание каналов климат
контроля А100 44 взято с сайта http://20v.org/
Оригинал
|
DIAGNOSTIC CHANNEL |
CHANNEL DESCRIPTION |
CHANNEL VALUES |
|
01 |
System Error |
00 = no system error |
|
02 |
Measurement Value of inside temp sensor G86
on roof |
Depends on temp. (table, Section D8-310) |
|
03 |
Measurement Value of inside temp sensor G56
on instrument panel. |
Depends on temp (table, Section D8-310) |
|
04 |
Measurement Value of outside temp sensor G57 (plenum) |
Depends on temp (table, Section D8-240) |
|
05 |
Measurement Value of outside temp sensor G17 (cowl) |
Depends on temp (table, Section D8-240) |
|
06 |
Measurement value of coolant temp sensor
G62. |
Depends on temp (table, Section
D8-320) Note: Display value for vehicles without coolant temp sensor 255
= open circuit |
|
07 |
Graphic display of output control info for
A/C programmer. |
See Section D8-40 |
|
08 |
Actual value of feedback potentiometer on
temp regulating flap servo motor, v68 |
Dep on prog: Numerical
value for the position of the servo motor is shown. |
|
09 |
Spec value of feedback potentiometer on temp
regulator flap servo motor |
Dep on prog:
ONLY CHECK when value in CH 8 is between 30 and 200. |
|
10 |
Specified voltage on fresh air blower |
Specified in volts |
|
11 |
Vehicle Electrical System Voltage |
Depends on instantaneous operating condition
greater than 9.5 volts. |
|
12 |
Total of Electrical system voltage
interruptions - values between 5 and 9.5 volts. |
Depends on running performance since display
was last erased. |
|
13 |
Program Number |
No determination... no use in troubleshooting
|
|
14 |
Switch position on high pressure switch F118
(red housing) |
0-5 (high pressure switch closed) |
|
15 |
Specified voltage on fresh air blower V2 in
volts |
Depends on program |
|
16 |
Pulse Counter |
No significance |
|
17 |
Graphic display of compressor shut-off
conditions |
Depends on program, see sec. D8-50 |
|
18 |
Graphical display of electrical outputs |
Depends on program, see sec. D8-60 |
|
19 |
Number of times the compressor shut off via
high pressure switch F118 (red housing) |
Depends on running performance since display
was last preset. |
|
20 |
Number of times the compressor shut off via
high pressure switch F118 (red housing) since last ignition switch cycle or
reset from OFF button |
Note: After 8th shut
off during a driving period, the compressor does not switch on again. |
|
21 |
Program number |
Not significant |
|
22 |
Speed signal |
00 when vehicle stopped |
Корявенький перевод J